|
Tender Corrigendum :
|
| Tender Corrigendum | Bid Cancel order of NIB F02(181)/RMSCL/Proc/SS MD/NIB-17/2024/4089 Dated- 04.11.2024 | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Amendment Specification in bid NIB-17/2024/4089 Dated- 04.11.2024 | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Feb 13 2025 12:00AM to Feb 24 2025 12:00AM Date Extension of NIB-17/2024/4089 Dated- 04.11.2024 | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Jan 30 2025 12:00AM to Feb 13 2025 12:00AM Date Extension of NIB F02(181)/RMSCL/Proc/SS MD/NIB-17/2024/4089 Dated- 04.11.2024 | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Jan 16 2025 12:00AM to Jan 30 2025 12:00AM Date extension of bid | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Dec 26 2024 12:00AM to Jan 16 2025 12:00AM Date extension in bid | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Dec 5 2024 12:00AM to Dec 26 2024 12:00AM Amendment in tender conditions, shelf life, Date extension and deletion of items from bid. | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers |
|
|
Product Detail :
|
E-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], "vdrl antigen (with +ve and -ve control) / rpr slide kit - specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis, 1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction., 2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen., 3. sensitivity & specificity should be 95% or more., 4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit., 5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2° c - 8° c., 6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit., 7. the test should be free from possible interferences with potentially cross reactive sera., 8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity., 9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), ", double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7' midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, "aortic punch 3.6 , length betwwen 6 to 7' midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for , easy insertation by straight or button , hole tech, should have long and short , handle confirguaration, sterile packing, ", biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., "programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above , should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), ", "programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above , should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing button on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx15cm or above), ", long term double lumen dialysis catheter size- 15fr x 27 cm long term double lumen dialysis catheter with kit accessories should be provided catheter, pull apart sheath, dialator, tunnelling stylet, guide wire j/s, with dispenser and injection caps, symmetrical tip retrograde and antigrade size- 15fr x 27 cm usfda certification along with iso, ce, closed suction catheter has isolated turbo cleaning chamber for cleaning catheter tip.catheter is made up of medical grade silicon material, catheter has zig-zag ports for better suctioning. twin peep seals. available in both endo
|
| Tender Detail : |
Surgical and Sutures #*. E-BID FOR RATE CONTRACT CUM SUPPLY AND EMPANELMENT OF SURGICAL AND SUTURE ITEMS |